For Air and Inert Gas PILOT VALVE For PR & SEQUENTIAL CONTROLLER
PI PR PILOT VALVE For PR SEQUENTIAL CONTROLLER
  • SPECIAL RUBBER DIAPHRAGM:High Pressure Resistant. Fast Opening and Long Life
  • DIE CAST ALUMINUM ANGLE BODY:Easy Mounting.
    Compact Size and High Flow Reverse Jet Dust Collector
  • DIN40 050 WATERPROOF COIL With DIN43 650 DIN PLUG:IP65,Continuois Cycle, 100%ED
  • EEXmII T4 Explosion-Proof coil is also available.
  • VOLTAGE TOLERANCE:±8%
  • ANY VOLTAGE AVAILABLE
  • 360oRotary Coil
  • PRESSURE:0.5-7 bar
  • FLUID TEMP.:-5~80oC
  • AMBIENT TEMP.:-15~50oC


TYPE PI : with integral pilot control

TYPE CODE PIPE G ORIFICE mm Cv DIAP. PARTS
PI 20 3/4 25 12 PCD025
25 1 30 25 PCD025
40 1-1/2 45 52 PCD040
50 2 57 85 PCD065
65 2-1/2 72 104 PCD065
80 3 80 140 PCD080



TYPE PR : for remote pilot control

TYPE CODE PIPE G ORIFICE mm Cv DIAP. PARTS
PR 20 3/4 25 12 PCD025
25 1 30 25 PCD025
40 1-1/2 45 52 PCD040
50 2 57 85 PCD065
65 2-1/2 72 104 PCD065
80 3 80 140 PCD080


SEQUENTIAL CONTROLLER
TYPE : PSC

 
TYPE
PSC10
PSC20
SPECIFICATIONS
Sequences Steps
1 - 10
1 - 20
Power
AC110V . 220V
Fuse
1A 250 V
Pulse Freequency
Range of Adjustability
0 - 200ms
Pulse Duration Range
of Adjustability
0 - 120 sec.
Operating Temp. Range
-10~50oC
Current Max.
5A
HIPOT
1000V



  • Small pilot valve is for PR only.
  • Coil and plug are not valid for type PR without pilot valve.
EXAMPLE
  1. PR50 denotes type PR, G2", without pilot valve.
  2. PI80D denotes type PI, G3", without pilot valve, standard coil with LED PLUG.
  3. PR25N denotes type PR, G1", with NS03-4 pilot valve, standard coil with DIN PLUG.

TYPE
DIMENSION mm
WIDTH
L'
L
H'
H
P
G
N.W.
kg
CODE
PI
20
75
52
90
108
130
--

5.0
0.7
25
0.7
40
137
72
140
148
178
G 1/4
1.5
50
170
95
181
183
228
--
G 3/4
3.1
65
3.0
85
206
118
215
206
264
G 3/8
2.6
PR
20
75
52
90
56
64
G 1/8
--
0.4
25
0.4
40
137
72
140
90
120
G 1/4
1.3
50
170
95
181
112
157
G 3/8
G3/4
2.9
65
2.8
80
206
118
215
136
194
G 3/8
2.4


 

 

L
x
W
x
H
193x110x50
208x165x50
L'
x
W'
180x95
188x145

TYPE
POWER CONSUMPTION
AC (VA)
DC (W)
NS
8.5 / 6.9
6.2
PI
CS
17.6 / 15.4
15.0


Pilot valves are used to operate
pulse valves from a remote location.

TYPE
PIPE
G
ORIFICE
mm
temp.
oC
O.P.D.
bar
Cv
BODY
MAT'L
PULSE
VALVE
NS03 - 4
1/8
3
-5 ~ 60
0 - 10
0.27
Brass
PR20
PR25
PR40
CS10 - 5
3/8
4
-5 ~ 80
0 - 7
0.54
Brass
PR50
PR65
PR80


Preface / Quick Reference Chart / Piston Series / Diaphragm Series /
Plunger Series / Pulse Valve / Y type Control Valve / Pneumatic Series /